Whatsapp

Advanced Electricity contracting Company

S-44 VLF (110 V)

Product Code : WMPAS44VLF

Brand : Sonel

Approximate Shipping Time : 3 to 4 week


Price : SAR169,120.00 SAR147,062.00



  • Evaluate the condition of cables using VLF or DC voltage

    Features:

    • Extremely compact high-power VLF test device
    • Easily portable for 1-2 people
    • Simple operation: menu-assisted control with industrial class OLED display
    • Fully automatic test sequence
    • Integrated timer 1-300 min with automatic tripping
    • Integrated breakdown detection
    • Integrated fault time detection
    • Voltage measurement direct at HV output
    • Protective ground connection
    • High voltage start key interlock
    • Protective circuit / indication in accord. with EN 50191
    • Leakage current measurement during VLF test

    Overview:

    The compact, robust and portable S VLF cable test sets are used for testing of medium voltage cables in accordance to the standards IEEE400, IEC 60502-2, CENELEC HD 620 & 621 and DIN VDE 0276/620 & 621. The test is carried out with a low strain practice with VLF (very low frequency) test voltage at 0.1 Hz frequency. VLF test enables detection of damages of the insulation within shortest test time. The S VLF series device can test cables with extruded insulation (XLPE-, PE-, EPR-insulation) as well as cables with paper-oil insulation (PILC). Cable sheath testing with direct voltage is also possible.

    Optional features:

    • Data logging (USB stick) for VLF test sets
    • Frequency extension: 0.05 + 0.02 Hz
    • Customized test cables
    • Transport case
  •  

  •  

      S-24 VLF S-36 VLF S-44 VLF S-44 VLF S-57 VLF
    Index WMGBS24VLF WMGBS36VLF WMGBS44VLF WMPAS44VLF WMGBS57VLF
    Power supply 230 V (±10%)
    10 A, 50/60 Hz
    230 V (±10%)
    10 A, 50/60 Hz
    230 V (±10%)
    10 A, 50/60 Hz
    110 V (100 V...127 V)
    15 A, 50/60 Hz
    230 V (±10%)
    10 A, 50/60 Hz
    Output voltage 0…24 kVRMS VLF 0,1 Hz
    (option: 0,05 Hz + 0,02 Hz)
    ± 0…34 kV DC
    0…36 kVRMS VLF 0,1 Hz
    (option: 0,05 Hz + 0,02 Hz)
    ± 0…52 kV DC
    0…44 kVRMS VLF 0,1 Hz
    (option: 0,05 Hz + 0,02 Hz)
    ± 0…62 kV DC
    0…44 kVRMS VLF 0,1 Hz
    (option: 0,05 Hz + 0,02 Hz)
    ± 0…62 kV DC
    0…57 kVRMS VLF 0,1 Hz
    (option: 0,05 Hz + 0,02 Hz)
    ± 0…62 kV DC
    Voltage
    waveshape VLF
    similar sine-wave, symmetrical, with True RMS measurement
    Voltage
    waveshape DC
    direct voltage, negative and positive polarity
    Overcurrent trip (DC) 10 mA

    Max. testable cable length, max. capacitance (VLF)

    *at a cable capacitance of approx. 0.25 μF/km

    up to 60 km
    (15 μF at 24 kVRMS,
    0,02 Hz)*
    up to 60 km
    (15 μF at 18 kVRMS,
    0,02 Hz)*
    up to 60 km
    (15 μF at 18 kVRMS,
    0,02 Hz)*
    up to 60 km
    (15 μF at 6 kVRMS,
    0,02 Hz)*
    up to 60 km
    (15 μF at 18 kVRMS,
    0,02 Hz)*
    Max. load at max.
    output voltage (VLF) and 0.1 Hz
    5 μF at 24 kVRMS 2,4 μF at 36 kVRMS 1,6 μF at 44 kVRMS 1,0 μF at 44 kVRMS 0,55 μF at 57 kVRMS
    Discharge - integrated
    automatic discharge
    device
    max. 9000 J max. 12500 J max. 12500 J max. 12500 J max. 12500 J
    Voltage measuring range -40…0…40 kV
    accuracy ±1%
    -60…0…60 kV
    accuracy ±1%
    -70…0…70 kV
    accuracy ±1%
    -70…0…70 kV
    accuracy ±1%
    -70…0…70 kV
    accuracy ±1%
    Current measuring
    ranges
    ±0…100 μA / 1 mA / 10 mA
    Operating temperature -20…+45°C
    Storage temperature -25…+70°C
    Duty continuous operation
    PC interface USB stick
    Construction in two parts: operation unit and high voltage unit
    Dimensions
    and weight
    Operation unit
    37 x 34 x 20 cm
    17 kg
    Dimensions
    and weight
    High voltage
    unit
    40 x 41 x 24 cm
    38 kg
    40 x 44 x 24 cm
    48 kg
    40 x 44 x 24 cm
    49 kg
    40 x 44 x 24 cm
    49 kg
    40 x 44 x 24 cm
    49 kg